Stem Cell Shipping and Cord Blood Transport
Hand-carry stem cell shipping for HSCs, cord blood and bone marrow — cryogenic or fresh, courier-accompanied door to door. UN3373 qualified, ISO 9001 quality-managed.
Embryo Links is an independent specialist courier registered in the UAE. We hand-carry embryos, eggs, sperm and stem cells clinic to clinic below −150°C in the aircraft cabin — never checked, never cargo — and we guarantee an unbroken cold chain, monitored and logged end to end. We run direct routes from the UK and Europe to Iran, Oman and the Gulf, and we handle the export and customs documentation at both ends.
We operate 29 published clinic-to-clinic corridors. From the UK and Europe we carry into Iran, Oman, the UAE and Saudi Arabia, and from Cyprus, Greece, Spain, Serbia, Bosnia, Romania, the Czech Republic, Pakistan, China, Malaysia, Indonesia and Tajikistan into Iran. Each corridor has its own page setting out the permits, airports and documentation.
How Stem Cell Shipping Works
Stem cell shipments split into two very different jobs. Cryopreserved material, such as cord blood units and stored HSC products, travels below −150°C in a dry shipper, the same way embryos and gametes do. Fresh apheresis product does not freeze at all. It moves at a controlled temperature against a clock measured in hours, and the flight is booked around the collection rather than the other way round.
Either way a courier stays with the shipment door to door. The product is not checked in, not consolidated with other freight, and not left in a depot overnight. For fresh product we plan the route backwards from the infusion slot, with a backup flight identified before departure.
Transplant centres ask about quality systems, so to be exact about ours: Embryo Links operates an ISO 9001 quality management system and every courier holds UN3373 qualification. We do not hold WMDA or FACT-JACIE courier accreditation, and we would rather say so plainly than let it be assumed.
We coordinate the customs and documentation side as part of the job, including the release paperwork the receiving centre needs before the product can clear.

A vial of haematopoietic stem cells may be the only available HLA-matched transplant unit for a patient in urgent need. A cord blood unit stored at a private bank represents years of premiums and a family's biological insurance policy. A fresh bone marrow harvest has a window of hours, not days.
We handle all main stem cell product types: cryopreserved HSC and cord blood units below −150°C; fresh apheresis products and bone marrow harvests at +2–8°C with tight timing requirements; and advanced cell therapy products including CAR-T cells on both the outbound and return legs of the supply chain.
Our operations team is available 24/7 for stem cell and cord blood transports — collection schedules are set by clinical teams, not courier preferences. Digital temperature logging is deployed on high-value transports to provide the receiving transplant centre with a continuous temperature record.
Get a QuoteCryogenic, below −150°C
Frozen HSC, cord blood and cell therapy products travel below −150°C in validated dry shippers with temperature logging. Any deviation is grounds for product rejection — we maintain the standard, every time.
Fresh Products at +2–8°C
Apheresis HSC products and bone marrow harvests travel in validated refrigerated containers. Fresh product is generally considered viable for up to 72 hours from collection, though the receiving transplant centre sets the limit for each case — we plan every route to the window they give us.
24/7 Availability
Bone marrow harvests don't happen at convenient times. Our operations team is contactable around the clock for stem cell transports — there are no exceptions to this.
CAR-T Cell Supply Chains
We handle both legs of CAR-T cell supply chains — the patient T-cell collection to the manufacturing site, and the modified cells back to the treating centre, often across international borders.
Cord Blood Banking
We work with both private family cord blood banks and public transplant registries for unit release and transplantation transport. The stakes are high — our standards match them.
Digital Temperature Logging
High-value and time-critical transports are equipped with calibrated electronic temperature loggers providing a continuous record. The receiving transplant centre gets full temperature history on arrival.
Unlike many pharmaceutical products, cryopreserved stem cells cannot be assessed after a suspected temperature excursion. A cell viability assay may look normal even after damaging devitrification — the damage affects engraftment capacity, not simple cell viability. A functionally compromised cell looks identical to a healthy one until it fails to engraft in the patient. This is why there is no "risk-based decision" available for a temperature breach with cryopreserved stem cells. Prevention is the only option.
Stem Cell Transport Across the Gulf
Embryo Links is a UAE company, and we handle both import and export of biological material through Oman, working with Oman International Hospital as our partner clinic there. It is a route we run, with the in-country relationship already in place rather than assembled per job.
It matters because the hard part of a Gulf transfer is rarely the flight. Cell therapy moves through countries where a cryoshipper arriving without the right prior authorisation does not get a second attempt. We coordinate the permits, the customs release and the airline approval as one piece of work, and the courier who carries the tank is the same person who holds the file.
We carry cryopreserved HSC and cord blood units in vapour-phase dry shippers, and fresh apheresis and marrow products in validated refrigerated containers, into and out of the region. Both travel in the cabin, in continuous custody, with a temperature logger running.
United Arab Emirates
Under the regulations endorsed by Council of Ministers Decision No. 6 of 2020, in force since January 2022 and administered by MOHAP, cord blood stem cells may not generally be imported into or exported from the UAE without prior formal permission. Securing that permission before anything moves is part of what we do.
Saudi Arabia
The SFDA requires an importation licence before minimally manipulated biological products intended for human application enter the Kingdom, and regulates cell and gene therapies separately under its advanced therapy framework. Which route applies depends on what the product actually is.
Oman
We move material in both directions through Oman International Hospital, our partner clinic. For a transplant centre, that means the receiving end of the route is already established — the clinic relationship and the documentation path are not being built from scratch around your shipment.
Onward and Inbound
We run the corridors that connect the Gulf to the UK, Europe and Asia, and our couriers hold the UN3373 qualification the category requires. Routing is built around airline approval for the shipper, which is secured per booking rather than assumed.
A transplant coordinator releasing a unit to a courier is entitled to ask what that courier works to. Ours are built around the published guidance for this category:
The WMDA Guidelines for couriers and the transportation of cellular therapy products require continuous possession of the product throughout, prohibit it travelling in checked luggage or inside the courier's own cabin bag, and tell couriers to make every effort to keep it away from X-ray and other irradiation screening. We go further than the last one. We do not permit X-ray at all — manual inspection is secured in advance, or the shipment does not travel.
Those same guidelines ask a commercial courier company to operate a quality management system covering courier selection, training, incident management and corrective actions. That is what our ISO 9001 quality management gives us, and it is why we issue a written agreement per leg rather than a consignment note.
FACT-JACIE and NetCord-FACT set the clinical standards our receiving centres work to — cord blood held at or below −150°C in transit, continuous temperature recording, product identity verified on arrival. We are a courier, not an accredited cell therapy facility, and we do not claim otherwise. What we do is make sure nothing we carry is the reason a centre has to reject a unit.
Last reviewed: 6 November 2026.
Disclaimer: The information provided on embryolinks.com is for general informational and educational purposes only. It does not constitute legal, regulatory, or medical advice. International transport protocols for human tissues and cells are highly subject to change and specific clinic policies. Readers should consult with licensed medical professionals, authorized clinics, and legal advisors before arranging any international biological shipments. Use of this information is strictly at your own risk.
Discuss Your Transfer With Us
Every journey starts with a conversation. Tell us what you need to move, where it's going, and when — we'll confirm what's required, what it costs, and how we'll handle it.
We respond within the hour. All staff hold UN3373 qualification. CAA certified. ISO 9001 quality management.